Beer line cleaning

Standard operating procedure

Beer Line Cleaning SOP

To be done once a week

  • Put one pint of beer line cleaner inside an empty 10 litre detergent bottle and top-up with water or half pint for 5 litre detergent bottle.
  • Connect product head with detergent bottle.
  • If installed, press fob detector so that it is filled completely with the cleaning solution.
  • Open the tower tap and pour approximately 3 litres (around 5 1/2 pints) of the cleaning solution or until the cleaning solution looks clear.
  • Disconnect head from detergent bottle. *Done to prevent leaks and loss of CO2.
  • Cleaning solution should be left for 1-2 hours in the system.
  • After reconnecting the head, pass the remaining cleaning solution from the tower.
  • Pass 5 to 10 litres of clean water through each system down the tower.
  • When connecting a new keg after line cleaning, ensure that enough beer is passed to displace the water present in the line. *Some fobbing may be seen until the line clears.

In case of queries or system failure, please contact Technical Support Services:

Monday to Friday: 7am till 3pm – Tel 2381-4337/9
Afternoon service: noon till 8pm – Mob 9949-9989
Saturdays, Sundays & Public Holidays: 10am till 5pm – Mob 9949-9989